1Fox &TheHound 3TRIPLETTInstruction Manual

Seite 2 - 1: Introduction

105.2.5: Earphone JackAccepts standard 1/8" (3.5mm) mini phone plug, either monoor stereo. For use with electromagnetic (dynamic) earphonesfrom

Seite 3 - 2: Key Features of the FOX

116: Fox and Hound 3 Control Locations (See Figures 1 and 2)ALEDBFunction SwitchCTone SwitchDModular PlugEAlligator ClipsBTRIPLETTTONE HI L

Seite 4

12AAConductive PlasticDuckbill TipBBMetal Conical TipCCLED LightsDDSignal Strength IndicatorEEPower ButtonFFSensitivity ControlGGEarphone JackHHBatter

Seite 5

137: Getting Started7.1: The FOX7.1.2: Installing a standard 9 volt battery in the FOXRemove the screw on the back of the case. Remove thecase fron

Seite 6

14shortening of the battery’s life may result. DO NOT connectto the line in Normal Polarity. Damage to the battery mayresult.7.1.4: Testing the Bat

Seite 7 - 5: Specifications

15tery to be fully inserted. The finger tab on the Strap shouldbe sticking out of the Battery Compartment. This tab is usedto remove the battery. Fold

Seite 8

16gator clips. Notice how the loudness of the warble soundincreases, and how the brightness of the Signal StrengthIndicator (DD) increases as the prob

Seite 9

17rescent lights off and using the HOUND 3’s built in lights(which do not produce any noise).7.4: Choosing a Probe TipThe HOUND 3 is supplied with 2

Seite 10

18Helpful Hint:Almost any type of earphones whose plug will fit into theEarphone Jack will work. Some types will work better thanothers. An earphone w

Seite 11 - FOX Control Locations

19If the target wire is connected to other wires and circuits,for example, to switches, lights, relays, transformers, etc.,the FOX TONE will pass thro

Seite 12 - Hound 3 Control Locations

2Fox and Hound 3 Instruction ManualTable of Contents1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 32. FOX Features .

Seite 13 - 7: Getting Started

20General Rules for Effective Tracing:…. Do what works best. Try both LINE/GROUND and LINE/LINE tracing (see following text).…. Separate wire

Seite 14

21Helpful Hint:Although the FOX does not require a battery when generat-ing a tone when Loop Current is present, if a battery is in theFOX, it will be

Seite 15

22the modular jack to be tested, or connect the Alligator Clips(E) to the line to be tested (Do not use the Modular Plug andthe Alligator Clips simult

Seite 16

23nect the alligator clips or the modular plug to the line to betested. The FOX will not seize the line on most phone sys-tems.8.1.3: CONTINUITY / T

Seite 17

24NOTE: Some handsets may not operate properly at the powerlevel supplied by the FOX.TRIPLETTTONE HI LOCONTINUITYTALKWARBLEOFF / LINE POLARIT

Seite 18

258.1.4: TONE: Wire Tracing, Identification, & Open FaultsThe uses of the FOX Tone mode can usually be divided intothree categories . . . tracing

Seite 19

26The FOX’s tracer tone can be shorted out by any loads onthe target wire. All loads must be disconnected from the tar-get wire.Crosstalk may occur in

Seite 20 - OPERATING INSTRUCTIONS:

278.1.4.2: Wire Tracing Methods:There are two basic wire tracing methods . . . “floating” and“grounded”.In the floating method (also called Line to L

Seite 21

28TRIPLETTTONE HI LOCONTINUITYTALKWARBLEOFF / LINE POLARITYMULTI-WIRE CABLETERMINALSTARGETWIRESFigure 4Floating or Line-to-Line Tracing

Seite 22

29In the grounded method (also called Line to Ground), oneclip of the FOX (either the red or green) is connected toearth ground or a “fake ground”, a

Seite 23

3When used together, the FOX and HOUND 3 aids in identify-ing, locating, and tracing wires, cables, and other conduc-tors. When the FOX is used to app

Seite 24 - FOX supplying “Talk Power”

30TRIPLETTTONE HI LOCONTINUITYTALKWARBLEOFF / LINE POLARITYMULTI-WIRE CABLETERMINALSTARGETWIREFigure 5Grounded or Line-to-Ground Tracing

Seite 25

31Helpful Hints:Extension pieces of wire, or long clip leads, can be used toconnect the FOX to a ground or fake ground. The extensionwire can be hundr

Seite 26

32nect to the phone line and ground.To identify the wires, if using the floating method, momen-tarily short the suspected wires together while listen

Seite 27

33At the other end of the wires, connect one of the clips of theFOX to a good earth ground. Experimentally connect the otherclip of the FOX to one wir

Seite 28 - Figure 4

34or fake ground. This will boost the tracer tone, and may pro-vide an adequate trace. The strongest trace will be obtainedwhen using the grounded met

Seite 29

35It can be done, but the HOUND 3 must be held very close tothe end of the cable to pick up any signal. To apply a floatingsignal to a coax, connect o

Seite 30 - Figure 5

36It is not unusual for the loose turn-able part of a coaxialconnector to have poor electrical contact to the cable shielduntil it is screwed on to it

Seite 31

378.1.4.5: Power Wires:The FOX and HOUND 3 cannot trace or identify “live” powerwires. To use a FOX and HOUND 3 to trace a power wire,power must be r

Seite 32

38ably the target wire. If the signal is not completely killed, thewrong wire has been selected, or there is an open fault inthe wire, and crosstalk i

Seite 33

39to the other wire. Notice that at approximately the midpointbetween the wires, the tracer tone becomes very weak. Thisis the “null point” . . . the

Seite 34 - WEAK TONE

43: Key Features of the HOUND 3• New Headlights to help light your way in dark areas and reduce florescent light noise!• Streamlined Design allow

Seite 35

40Reposition the test wires so that they are inline with eachother, with a small gap between them (1/16" to 1/8"). SeeFigure 8. Again, trace

Seite 36

41Now, attach one of the clips and the wire attached to it to agood earth ground. See Figure 9. The HOUND 3 should pickupvery little signal from the g

Seite 37

42For the most accurate simulation, lay out a serpentine pat-tern on the floor similar to that in the ceiling, and locate theopen in different places,

Seite 38

43cations, the far end of the wire must be disconnected fromany loads or any other wires, or the tracer tone will be shortedout, or it will migrate in

Seite 39 - TRIPLETT

44If tracing wires in a boat that is out of the water, attach oneclip of the FOX to the metal trailer frame, or to a groundedmetal object. As before,

Seite 40

45on the unfaulted wires, the tracer tone will be reduced inlevel on the unfaulted wires, and make locating the openeasier. In fact, if the other wire

Seite 41 - WEAK SIGNAL

46“pick up” signals from electrical devices other than the FOX.Probably the most notable signal, a buzzing sound, comesfrom fluorescent lights. Other

Seite 42

47which wire is the target wire. In this situation, it often helpsto reduce the Control setting, so changes in loudness areeasier to discern. Also, th

Seite 43

48In some situations, the HOUND 3 may have a tendency to“feedback” at high Sensitivity settings. The feedback maysound like a howling or squealing so

Seite 44

49use of the conductive plastic probe is recommended. Theplastic probe is only slightly conductive, and usually causesno disruption of equipment opera

Seite 45

54: Safety Warnings and Cautions4.1Do not connect FOX or HOUND 3 to any source of AC power.AC voltages above 30 volts can be dangerous, and may re-sul

Seite 46

5010: Warranty InfoONE YEAR LIMITED WARRANTYThe Triplett Corporation warrants instruments and test equipmentmanufactured by it to be free from defecti

Seite 47

51ALL WARRANTIES IMPLIED BY LAW ARE HEREBY LIMITED TO APERIOD OF ONE YEAR FROM DATE OF PURCHASE, AND THE PRO-VISIONS OF THE WARRANTY ARE EXPRESSLY IN

Seite 48

52© Triplett Corporation All Rights ReservedTRIPLETTTriplett Corporation One Triplett Drive Bluffton, O

Seite 49

64.5Use caution when working with telephone lines. They cansupport dangerous voltages. 50VDC is often present, and100VAC may be present during ringing

Seite 50 - ONE YEAR LIMITED WARRANTY

75: Specifications5.1: FOX Specifications5.1.1: Telephone Loop mA and Line Polarity Test:Indication: Red LED lights to indicate presence of Loop mA

Seite 51

85.1.5: Visual Continuity:LED lights when continuity is establishedOpen Circuit Voltage: 10v max.Test Current: 35mA max5.1.6:

Seite 52

95.1.9: NiCad Charging Current: Approx. 9mA5.1.10: Dimensions: Case: 3.7"H x 2.4"W x 1.1"T(93mm x 61mm x 28mm) Leads: All